检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗德祥
机构地区:[1]广东省国际工程建筑设计有限公司,广州510100
出 处:《制冷》2005年第B05期107-111,共5页Refrigeration
摘 要:成都新城市广场是集购物、餐饮、娱乐、休闲、文化于一身的大型综合购物中心。简述了该工程的通风、空调、防排烟设计,重点介绍冷热源设计和冷冻水系统设计特点。根据环境和工程特点,冷源选用5台离心式冷水机组和1台螺杆式冷水机组,热源选用了3台常压式或真空式热水机组,为了平衡冷冻水分系统的平衡,安装了自力式压差控制阀。The Chengdu New- city Plaza is the collection shopping, the dining, the entertainment, the leisure, the culture in a body large- scale comprehensive shopping center. Present the air conditioning, ventilation and the smoke management system design of the building. Introduce the cold heat source design and cold water system characteristic with emphasis. According to the environment and the project characteristic, the cold source chooses five water cooled centrifugal chillers and one water cooled screw chiller, the heat source chooses three atmospheric pressure type or vacuum type hot water unit, in order to balance the cold water subsystem, has installed the self- reliant differential pressure control valve。
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]