生物接触氧化技术在生活小区污水处理中的应用  被引量:11

Application of Biological Contact Oxidation to Residential District Waste water Treatment

在线阅读下载全文

作  者:王月红[1] 王正林 杨敏[2] 

机构地区:[1]无锡市自来水总公司,江苏无锡214073 [2]中国科学院生态环境研究所,北京100085

出  处:《净水技术》2005年第4期28-30,共3页Water Purification Technology

摘  要:利用悬挂式软性纤维填料制备了生物接触氧化塔,并对生活小区污水进行处理,三个月的试验结果,表明:在HRT=3h的条件下,当原水COD在300~400mg/L,氨氮在30~80mg/L范围时,出水氨氮<1mg/L、COD<50mg/L、SS<15mg/L,此时,系统硝化负荷最高达0.50kg/(m3·d)有机负荷最高达3.2kg/(m3·d)。由实验结果得出,HRT为1.5h,在有机负荷2kg/(m3·d)时,水力负荷是影响硝化的关键因素。Bio-contact oxidation tower with hanging fibre media was used to treat the wastewater of a residential district. When HRT is 3h,COD is between 300 and 400 mg/L and NH3-N between 30 and 80mg/L in the influene,after treatment COD decreased to 50mg/L,NH3-N〈1mg/L and S〈15mg/L in the efluent in case of maximal nitrogen load 0.5kg/(m^3 · d )and maximal organic load 3.2kg/(m^3 · d). The results showed when organic load 2.0kg/(m^3 · d) ,the hydraulic load is the key factor for nitrofication,and HRT must be greater than 1.5h.

关 键 词:生物接触氧化 污水处理 水力负荷 有机负荷 生物接触氧化技术 生活小区 生物接触氧化塔 应用 软性纤维填料 小区污水 

分 类 号:TU984.12[建筑科学—城市规划与设计] X791.031[环境科学与工程—环境工程]

 