检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]河北省矾山磷矿检测中心,河北涿鹿075641 [2]河北理工大学化工与生物技术学院,河北唐山063009
出 处:《化学工程师》2005年第8期21-22,共2页Chemical Engineer
摘 要:研究建立了在样品处理过程中不使用甲醛并用G4玻璃坩埚过滤四苯硼钾沉淀,微波加热恒重,测定硫酸钾、氯化钾中氧化钾含量的方法。确定了微波功率300W,加热干燥恒重时间6min。方法省时、简便、实用、无毒害、符合生产要求。The paper studied and set up a methad of determaining K20 in K2SO4 and KC1 by using C4 glass pot to filtrate four benzene boron potassium deposition and nficrowave heating to constant weightiness, but not using formaldehyde in the process, Through the experiment, some conditions were obstained that the microwave power was 300W, the time of heating and drying to constant weightiness was 6 minites. The method was time - saving, simple, utility and no poisonous harm, according with produce requirement.
正在载入数据...