摘  要:研究了用固相萃取富集,二极管矩阵检测器检测,反相液相色谱法测定大花红景天中微量元素硒的方法。样品中硒用邻苯二胺显色剂作柱前衍生,WatersSep-park-C18固相萃取微柱富集硒的邻苯二胺络合物,然后用乙腈和甲醇为流动相,WatersμBondapakC18色谱柱为固定相分离,用二极管矩阵检测器检测。方法相对标准偏差为2·40%,标准回收率为98·67%。该方法用于大花红景天样品的分析,结果令人满意。The method for the determination of selenium in health food materials by solid phase extraction-high performance liquid chromatography was studied. The selenium was pre-column derived by o-phenylendiamine. The chelate complex can be extracted by Waters Sep-Park-C18 chromatogram column and eluted by acetonitrile, then separated on a Waters μBondapak C18 chromatogram column(3.9mm×300 mm) and monitored by photodiode array detector. The relative standard deviation is 2.40%, and the recovery is 98.67% . This method can be applied to the determination of microamount of selenium in Rhodiola Crenulata with satisfactory results.

关 键 词:邻苯二胺 固相萃取富集 高效液相色谱法  微量元素硒 大花红景天 测定 反相液相色谱法 相对标准偏差 标准回收率 