盐密、灰密对防污闪涂料憎水迁移性的影响  被引量:4

Influence of Density of Salt and Density of Dust on Hydrophobicity Migration of Anti-flashover Coating

在线阅读下载全文

作  者:袁明仁[1] 唐政 李自勇 

机构地区:[1]国网电力科学研究院,湖北武汉430074 [2]重庆市超高压公司,重庆400030

出  处:《水电能源科学》2010年第9期148-150,共3页Water Resources and Power

摘  要:依据电力系统污区分布,通过静态接触角的测量及HC喷水分级法研究了涂层的厚度、盐密及灰密对涂层憎水迁移性的影响。结果表明:涂层的厚度、盐密对PRTV涂层的憎水迁移性影响较小,而涂层灰密对其憎水迁移性影响较大,灰密越大涂层的憎水迁移越困难。研究结果对涂层在污秽地区的运行具有指导意义,并为深入探讨灰密和盐密对防污闪涂料电气性能的影响提供理论依据。According to the distribution of dirty area in power system,the influence of coating thickness and density of salt and dust on migration of hydrophobicity coating is analyzed by measuring the static contact angle and using HC water spray classification method.The results show that coating thickness and density of salt have little effect on migration of hydrophobicity for PRTV coating while the density of dust have large effect;the lager the density of dust is,the more difficulty the PRTV coating moves.The study results provide an important guiding meaning for the coating operation in dirty area and a basis theory for investigating the influence of density of salt and dust on electricity property of anti-flashover coating.

关 键 词:防污闪涂料 憎水迁移性 Migration Salt 涂层 静态接触角 指导意义 污区分布 污秽地区 理论依据 结果 厚度 电气性能 电力系统 分级法 运行 喷水 困难 测量 

分 类 号:TK79[动力工程及工程热物理—流体机械及工程] TV7[水利工程—水利水电工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象