两种β-HCG检测的方法比较  被引量:4

The Application and Comparison of the MEIA Assay with Colloidal Gold for β-HCG

在线阅读下载全文

作  者:凡瞿明[1] 张蕾[2] 何兰[1] 周彤[1] 邓仁兵[1] 程吉兵[1] 赖猛[1] 

机构地区:[1]川北医学院附院检验科,四川南充637000 [2]川北医学院检验系,四川南充637000

出  处:《医学检验与临床》2006年第5期33-34,共2页Medical Laboratory Science and Clinics

摘  要:目的评价微粒子酶免化学发光法和免疫胶体金试纸法检测β-HCG的方法优劣。方法收集104例患者血清同时用微粒子酶免化学发光法和免疫胶体金试纸法检测血浆中β-HCG并对结果进行分析比较。结果微粒子酶免化学发光法检测血浆中β-HCG阳性率明显高于免疫胶体金试纸法,两种方法检测结果有显著性差异(P<0.01)。结论微粒子酶免化学发光法测β-HCG灵敏度高、更精确、更具有临床应用价值。Objective To evaluate the applications of the MEIA and colloidal gold assay for β-HCG.Methods 104 cases serum samples,were collected and tested by the MEIA and colloidal gold method.The results from the 2 assays were analyzed and compared.Results The positive rate of the MEIA assay had obvious difference with that of colloidal gold.Conclusion MEIA is more sensitive,precise than colloidal gold in assaying β-HCG,so the former is more valuable in clinical application.

关 键 词:检测 方法 化学发光法 胶体金试纸法 微粒子 免疫 显著性差异 应用价值 血浆 灵敏度高 患者血清 阳性率 收集 评价 临床 

分 类 号:R446.6[医药卫生—诊断学]

 