检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]公安部四川消防研究所,四川都江堰611830 [2]四川天府防火材料有限公司,四川都江堰611830
出 处:《安全与环境学报》2005年第4期97-100,共4页Journal of Safety and Environment
基 金:四川省科技攻关项目(20048801S)
摘 要:研制了一种可在潮湿环境中使用,火灾发生时无有害气体产生的环保型隧道防火涂料。涂料的粘结强度为0.4MPa,耐水性大于20d,烟气毒性达到AQ1级。按ISO834曲线升温,涂层厚度13mm时,耐火极限达到3.5h;按碳氢曲线升温,涂层厚度20mm时,耐火极限达到3.0h。为防止涂料加水拌和后沉淀分层,增加涂料的和易性,研制了一种分散剂。产品已工业化生产并应用于一些标志性隧道工程。Based on the introduction to the theories of tunnels, tunnel fire design codes both at home and abroad and fire behaviors of enforcement concrete structure, the authors have developed an environment-friendly fire proofing coating which can be used in damp surroundings without triggering any noxious gases in fire. The bonding strength of the coating is 0.4 MPa (tested by the GB 14907—2002), the water-repellent capability should be greater than 20 d (tested by the GA 98—1995) with the toxicity of its fire effluents reaching AQ-1(tested by the GA 132—1996) . The duration of the fire resistance reaches 3.5 h when the thickness of the coating is 13 mm(tested by the fire curve of ISO 834), duration of fire resistance reaches 3.0 h when the thickness of the coating is 13 mm (tested by the fire curve of H-C). In order to avoid the isolation of the coating and increase its feasibility, a dispersant has been developed by the authors. The products we have manufactured in the factories and have already been adopted in some big engineering projects.
分 类 号:X701[环境科学与工程—环境工程]
正在载入数据...