罗丹明B荧光猝灭法测定痕量Cr(VI)的研究  被引量:12

Determination of Cr(VI) by fluorescence quenching method

在线阅读下载全文

作  者:曾铭[1] 李树伟[1] 李小燕[1] 

机构地区:[1]四川师范大学化学学院,成都610066

出  处:《西南民族大学学报(自然科学版)》2005年第5期728-730,共3页Journal of Southwest Minzu University(Natural Science Edition)

摘  要:基于六价铬与碘化钾反应生成了单质碘,碘可以使罗丹明B发生荧光猝灭,从而间接测定六价铬的含量.六价铬浓度在0.01-0.5μg/mL范围内,荧光强度差值与六价铬浓度呈线形关系,线性回归方程为△F=121.58CCr(VI)(μg/mL)+16.17,相关系数r=0.9990,检测限为2.4ng/mL.该方法简便,快速,灵敏度高,已用于环境样品中六价铬的测定,回收率在99.8%-104.2%,结果满意.A simple and sensitive fluorescence quenching method for determination of Cr(VI) is investigated. The method is based on fluorescence quenching of Rhodamine B by reaction of Cr(VI) with potassium iodide giving iodine(I2). The calibration graph is linear over the range 0.01-0.5μg/mL Cr(VI). The linear equation is △F=121.58CCr(VI)(μg/mL)+16.17, and the relative coefficient is 0.9990. The detection limit is 2.4ng/mL. The method has been applied successfully to the determination of Cr(VI) in environmental water. The recovery of this method for detecting Cr(VI) is 99.8%-104.2% and the result is satisfactory.

关 键 词:荧光猝灭法 单质碘 罗丹明B CR(VI) 

分 类 号:O626[理学—有机化学]

 