半刚性连接对钢管混凝土框架结构设计的影响  被引量:4

EFFECT OF SEMI-RIGID CONNECTIONS ON DESIGN IN CONCRETE FILLED STEEL STUB FRAME

在线阅读下载全文

作  者:孙修礼[1] 蒋永生[1] 梁书亭[1] 谢士华[1] 王群依 

机构地区:[1]东南大学教育部混凝土与预应力混凝土重点实验室,南京210096 [2]江苏省建筑工程管理局,南京210005

出  处:《钢结构》2005年第4期29-31,61,共4页Steel Construction

基  金:江苏省"六大人才高峰"资助项目(编号7605009063)。

摘  要:钢管混凝土框架结构中梁柱的连接往往是半刚性的,设计中把梁柱连接假定为完全刚接或完全铰接都是不合理的。探讨了半刚性连接对钢管混凝土框架结构内力、位移等的影响,导出了半刚性连接钢管混凝土框架结构在竖向荷载下梁端弯矩的求解公式,对水平荷载作用下标准反弯点高比计算公式进行修正,并提出了考虑半刚性连接的设计建议,可供工程设计人员参考。Generally the beam-column connections of concrete filled steel tube frame are semi-rigid. It was unreasonably to assume that the connections were rigid or normally pinned in design. Such effects as internal force and displacement that the semi-rigid connections had on the concrete filled steel tube frame were discussed. The formulas used to solve the beam moment under vertical load were deduced; furthermore, the formulas to determine the height ratio of standard inflection point were modified. Design suggestions on considering the semi-rigid connections have been made. The proposed methods may supply references for the engineers of semi-rigid concrete filled steel tube frame structure design.

关 键 词:钢管混凝土框架结构 半刚性连接 内力 层间位移 标准反弯点高比 框架结构设计 钢管混凝土 混凝土框架结构 水平荷载作用 工程设计人员 

分 类 号:TU398.9[建筑科学—结构工程]

 