摘 要:基于在硫酸介质中,铁(Ⅲ)能灵敏地催化高碘酸钾氧化偶氮氯膦-mA(CPA-mA)褪色,建立了测定痕量铁(Ⅲ)的新方法,同时研究了该方法的动力学条件.方法检出限为5.72×10-8g/L,10 mL溶液中,铁的线性范围0~0.5μg.方法用于各种水中痕量铁(Ⅲ)的测定,回收率在98%~102%之间,RSD在1.9%~2.6%之间.A new catalytic spectrophotometric method for the determination of trace iron(Ⅲ) has been developed. The method is based on the catalytic effect of iron(Ⅲ) on the oxidation of chlorophosphonazo-mA with KIO4 in the medium of H2SO4.The detection limit of this method is 5.72 × 10^-8g/L for iron(Ⅲ) and Beer' s law is obeyed for iron(Ⅲ) in the range of 0 - 0.5 μg/10 mL. RSDs are 1.9 % - 2.6 % and recoveries range from 98 % to 102 %. The method has been applied to the determination of trace iron in the water with satisfactory results.