检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:江飞飞[1] 江楠[1] 卞淞霖[1] 王延顼[1] 邓波[1]
机构地区:[1]华南理工大学工业装备与控制工程学院,广东广州510641
出 处:《石油化工设备技术》2005年第4期30-32,共3页Petrochemical Equipment Technology
摘 要:对空气压缩机后冷却器流程的选择提出了新见解。文章分析指出,综合空气压降和总传热系数两方面因素,一般情况下,建议将折流板间距与壳体内径的比值(h/D)设置在0.6~0.7之间并选择热空气走壳程的方案;若仅希望冷却器具有较低的空气压降,建议将折流板间距与壳体内径的比值(h/D)设置在大于0.7的范围,并选择热空气走管程的方案。A new opinion on flow sheet selection for post cooler of air compressor was put for- ward in this article.The analysis of this article denoted that:synthesizing the two factors of air pressure drop and overall heat transfer coeffi- cient,the ratio(h/D)between baffle space and inside diameter of shell should be 0.6 to 0.7 un- der common condition,and selected the plan of hot air feeding into the shell side.If cooler with lower pressure drop,the ratio(h/D)between baffle space and inside diameter of shell should be larger than 0.7,and selected the hot air feed- ing into tube side.
分 类 号:TH45[机械工程—机械制造及自动化]