碳钢—铝翅片管束复合放热特性及接触热阻的实验研究  被引量:3

Experi mental Study on Characteristic of Compound Convection and Contact Heat Resistance in the Cross Gas over Compound Fined Tube Banks

在线阅读下载全文

作  者:马其良[1] 曹丽丽[1] 吕新颜[1] 李朋[1] 

机构地区:[1]上海理工大学动力工程学院,上海200093

出  处:《工业炉》2005年第5期1-3,11,共4页Industrial Furnace

基  金:上海市教委发展基金项目(F20111).

摘  要:介绍通过实炉实验研究获得了碳钢—铝翅片管束有水蒸汽冷凝换热时的复合放热特性及接触热阻的情况,实验获得的关联式对燃气锅炉冷凝式换热器的设计及运行有参考指导作用。The characteristic of compound convection and con tact heat resistance of saving energy of a boiler with rated output-4 ton steam per hour refitted by adding a condensing device were introduced. In addition, the testing correlation of the compound convection including condensation over elytriform tube banks scoured by low speed smoke were acquired, which had the referential value to design and operation.

关 键 词:碳钢—铝复合翅片管束 冷凝 接触热阻 复合放热特性 实验研究 