空调性能测试中空气状态参数的精确计算  被引量:2

Accurate Calculation of Air Property for the Capacity Test of Air-Conditioner

在线阅读下载全文

作  者:王溢芳[1] 闻建中[1] 舒国安[1] 王雷[1] 夏玲[1] 

机构地区:[1]合肥通用机械研究院,安徽合肥230031

出  处:《流体机械》2005年第9期83-85,47,共4页Fluid Machinery

摘  要:根据部分已知的空气状态参数,通过查阅焓-湿图表可粗略估算出未知的空气状态参数。工程施工或精度要求不高的情况下,该方法能满足要求;但在精度要求比较高的情况下,尤其是在空调产品检测和高精度试验时,依靠查阅图表的方法就不能满足要求了。本文结合空气状态参数计算软件,论述了空气状态参数的高精度计算方法,并着重介绍了为此而专门编写的计算机算法。Generally, we can measure several air properties directly, such as dry-bulb temperature, wet-bulb temperature, and barometric. Using the psychrometric chart with these data, we can get the other air properties inaccurately. The above - mentioned mothod of air property calculation is enough for generic application, but not enough for the specific application that need high accuracy, such as the capacity test of air conditioner, because of its big error amount. Consequently we need the better calculation to meet the high precision. A accurate calculation of air property has been discussed.

关 键 词:空气状态参数计算 算法 空调 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程] TP39[自动化与计算机技术—计算机应用技术]

 