电催化氧化法处理阴离子表面活性剂废水  被引量:10

Treatment of Anionic Surfactant Wastewater by Electrocatalytic Oxidization Process

在线阅读下载全文

作  者:景长勇 崔建升[2] 冯辉[3] 吴韶梅[4] 

机构地区:[1]中国环境干部管理学院,河北秦皇岛066004 [2]河北科技大学环境科学与工程学院,河北石家庄050018 [3]华北电力大学环境科学与工程学院,河北保定071003 [4]河北科技大学化工学院,河北石家庄050018

出  处:《化工环保》2005年第5期368-371,共4页Environmental Protection of Chemical Industry

基  金:河北省科技厅课题(02276703D)

摘  要:采用自制电化学反应器对阴离子表面活性剂废水的电催化氧化处理进行了研究,考察了阳极材料、电解电压、电解时间、电极间距离、废水pH、废水电导率等对阴离子表面活性剂电解去除效果的影响,确定了最佳的处理条件.在电解电压为8 V、电解时间为30~40 min、电极间距离为2 cm、废水pH为8~10、废水电导率为0.620 ms/cm的条件下,阴离子表面活性剂的电解处理去除率可达96%以上.The electrocatalytic oxidation treatment of anionic surfactant wastewater was studied with a selfmade electrochemical reactor. Factors affecting the removal rate of anionic surfactant were investigated, such as anode material, electrolytic voltage, electrolytic reaction time, interelectrode distance, pH and conductivity of wastewater, and so on. At the optimum conditions of electrolytic voltage 8 V, electrolytic reaction time 30-40 min, interelectrode distance 2 cm, pH 8-10 and conductivity 0. 620 ms/cm, the removal rate of anionic surfactant is more than 96%.

关 键 词:阴离子表面活性剂 电催化氧化 电解 废水处理 

分 类 号:X506[环境科学与工程—环境工程]

 