检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]鞍钢集团公司化检验中心,辽宁鞍山114021
出 处:《冶金分析》2005年第5期32-34,共3页Metallurgical Analysis
摘 要:通过辉光光谱仪预溅射参数和积分时间等因素对钢中微量元素砷、铅、锑、锡辉光光谱行为的影响试验,建立了辉光放电发射光谱法同时测定钢中砷、铅、锑、锡的方法.测定范围分别为:w(As)=0.004 5%~0.008 7%,w(Pb)=0.000 2%~0.13%,w(Sb)=0.001 1%~0.072%,w(Sn)=0.003 1%~0.079%.该方法的精密度和准确度令人满意,对质量分数为0.003%~0.015%砷、铅、锑、锡的测定(n=9),RSD<2%,测定结果与认定值十分吻合.The influence of glow discharge parameters,such as time of presputter and integrating on the intensity stability of four elements in steel as well as the spectral behavior of the four elements in glow discharge were tested. Then a method for simultaneous determination of As, Pb, Sb and Sn in steel was established. The determination ranges are 0. 004 5 % - 0. 087 % for As, 0. 000 2 % - 0.13 % for Pb, 0.001 1% - 0. 072 % for Sb and 0. 003 1% - 0.079 % for Sn. Both accuracy and precision of this method are satisfactory. For determining 0. 003 % - 0. 015 % of As, Pb, Sb and Sn ( n = 9) , RSDs are less than 2 %. The determination results are agreement with the certified.
关 键 词:辉光放电发射光谱(GD—OES) 钢 预溅射 积分
分 类 号:TG115.33[金属学及工艺—物理冶金]