镁、铝的激光-时间分辨荧光测定  被引量:7

Laser-time Resolved Fluorimetric Determination of Magnesium(Ⅱ) and Aluminium(Ⅲ)

在线阅读下载全文

作  者:于水[1] 刘智慧[2] 王功鹏[1] 杜杰[3] 杨延安[4] 

机构地区:[1]北京放射医学研究所 [2]新疆军区军事医学研究所 [3]第二炮兵防疫防护环境监测队 [4]解放军80305部队防疫队

出  处:《分析化学》1996年第4期433-435,共3页Chinese Journal of Analytical Chemistry

摘  要:本文报道了用8-羟基喹啉-5-磺酸作荧光指示剂,采用激光-时间分辨技术进行镁、铝测定的新方法。在1~100μg/L的范围内,镁、铝的浓度和荣光强度是良好的线性关系(r>0.999),方法的检出限分别为2μg/L和1μg/L。用标准牛肝份对方法进行了验证,并用该方法对自来水进行了直接测试。A laser-time resolved fluorimetric determination of Mg2+ and Al3+ with 8-hydroxyquinoline-5-sulphonic acid enhancer was developed. Positive linear correlation (r=0. 999) in the range of 1 to 100 mg/L was found. The detection limits of aluminium and magnesium were 1 and 2 μg/L, respectively. The method was successfully verified by the determination of Mg in bovine liver (NBS 1577a) and was further used in the tap water analysis.

关 键 词:荧光分析   自来水 8-羟基喹啉 磺酸 

分 类 号:TU991.21[建筑科学—市政工程]

 