飞机用浮标应急电源的改进  

Improvement of the emergency power source of aircraft buoy

在线阅读下载全文

作  者:王永红[1] 杜向辉[2] 

机构地区:[1]国营第七五五厂,河南新乡453069 [2]海军装备部驻新乡地区航空军代室,河南新乡453069

出  处:《电池工业》2005年第5期282-284,共3页Chinese Battery Industry

摘  要:介绍了进口飞机浮标应急电源的国产化改进过程。报导了采用全密封镉镍电池代替原装开口式电池设计,电池性能达到了预期目标;试验证明,改进后的国产浮标电源性能优于原装浮标电源,缩短了维护周期,降低了维护成本,完全可以满足海上救护及应急指示的需求。The improvement of the original emergency power source for the imported aircraft was introduced. The vented battery was replaced by the sealed Ni-Cd battery, The results were satisfying, The test showed that the performance of the home made battery for buoy application was better than the former one. The maintenance cost was reduced. It could meet the requirements of sea rescue and emergency indication.

关 键 词:电池 浮标电源 维护 

分 类 号:TM912.2[电气工程—电力电子与电力传动]

 