摘 要:Fire Dynamics Simulator v3.0 was used to investigate and management in a realistic indoor sports center. An atrium fire test case assess fire smoke transport and ustrated the code's superiority over code-type empirical models for both accuracy and capability. Four fire scenarios in the Tsinghua University Sports Center were then simulated. The smoke layer's descent speed was predicted for each case. The importance of the door effect was revealed and an additional mechanical ventilation system for the building was proved to be of no help. The door effect must be carefully considered in future fire safety designs.Fire Dynamics Simulator v3.0 was used to investigate and management in a realistic indoor sports center. An atrium fire test case assess fire smoke transport and ustrated the code's superiority over code-type empirical models for both accuracy and capability. Four fire scenarios in the Tsinghua University Sports Center were then simulated. The smoke layer's descent speed was predicted for each case. The importance of the door effect was revealed and an additional mechanical ventilation system for the building was proved to be of no help. The door effect must be carefully considered in future fire safety designs.
关 键 词:computational fluid dynamics (CFD) sports center fire door effect smoke management
分 类 号:TU245[建筑科学—建筑设计及理论] TU998.13
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33