检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:莫继锋[1] 凌球[1] 郭兰英[1] 屈国普[1]
机构地区:[1]南华大学核科学技术学院,湖南衡阳421001
出 处:《南华大学学报(自然科学版)》2005年第3期5-8,共4页Journal of University of South China:Science and Technology
摘 要:针对放射性惰性气体在“Marinelli Beaker”(简称MB)容器中,用NaI(Tl)闪烁探测器测量γ射线.采用蒙特卡洛计算方法计算NaI(Tl)晶体对85Krγ射线的探测效率并与标准源实验刻度探测效率进行比较.应用Matlab软件对不同体积的MB容器的理论计算和实验刻度数据分别用最小二乘法进行拟合并比较.比较结果显示,理论计算值和实验数据在误差范围内是一致的.The efficiency of NaI (Tl)scintillation crystals detector for Marinelli Beaker with the noble gas radioactive source is calculated by Monte Carlo method and the experiment using ^85Kr standard source. The comparison between the theory calculation to the Marinelli Beaker of different volume using Matlab software and the experimental calculation data is made by the least square method. The comparison result shows that the theory calculation and the experimental data are equal in deviation.
关 键 词:蒙特卡洛 MATLAB 最小二乘法 γ探测效率 气体源
分 类 号:TL8[核科学技术—核技术及应用]