电位滴定法和反滴定法测定烯烃含量的比较  被引量:1

Contrast of Electrolytic Titration and Nverse Titration for Measuring Alkene

在线阅读下载全文

作  者:佟惠娟[1] 

机构地区:[1]江苏工业学院化学工程系,江苏常州213016

出  处:《当代化工》2005年第5期356-358,共3页Contemporary Chemical Industry

摘  要:比较了电位滴定法和反滴定法测定烯烃含量的准确性。结果表明,在所测定的质量分数范围内电位滴定法的相对误差为2%~10%;反滴定法的相对误差为-4.5%~8.5%。烯烃的质量分数在2%~10%之间时,电位滴定法比反滴定法的测量结果更加准确,相对误差约为2%~3%;烯烃的质量分数在0.040%~0.62%之间时,反滴定法比电位滴定法的测量结果更加准确,相对误差约为-3.5%^-4.5%。The electrolytic titration method was compared w:th the inverse titration method in this paper for the accuracy of the measuring alkene. The results showed that relative error of the electrolytic titration and the inverse titration was 2 % - 10 % and - 4.5 % - 8.5 % respectively within measured concentration. The electrolytic titration method was more accurately than the inverse titration method for 2 % - 10 % of alkene and the inverse titration method was more accurately for 0.62 % - 0. 040 % of alkene and relative error was 2 - 3 % and - 4.5 - 3.5 % respectively.

关 键 词:电位滴定 反滴定 烯烃的测定 

分 类 号:O655[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象