城市原生污水源热泵系统运行工况与参数特性  被引量:35

Operating Condition and Parameter Characteristic of Urban Wastewater Source Heat Pump System

在线阅读下载全文

作  者:吴荣华[1] 张成虎[1] 孙德兴[1] 

机构地区:[1]哈尔滨工业大学,黑龙江哈尔滨150090

出  处:《流体机械》2005年第11期73-76,19,共5页Fluid Machinery

基  金:黑龙江省科技攻关项目(04GCZ1474)

摘  要:基于工程实践,在一定的技术背景条件下,对污水源热泵系统的制热、制冷工况及特征参数做了全面测试,包括供暖空调效果、水源侧运行参数、系统能耗水平、典型工况等,得到各类运行参数特性曲线.研究表明,热泵系统运行效果良好,水源侧温度保持在7℃以上,全系统制热系数大于3.5,制冷系数大于4.0,典型水源工况为7.5~3℃.对污水源热泵系统设计与评价有参考意义.From the engineering practice, under some technology background, the characteristic parameters of heating and refrigeration status was roundly tested, including the heating or air condition effect, the wastewater' s parameters, the system' s energy wasting level, typical work status. The characteristic curves of each work parameter was given out. The study indicated that the work effect is good and the wastewater' s temperature is above 7℃, the heating COP is above 3.5, the air condition COP is above 4.0, the typical wastewater temperature was 7.5 - 3℃. It's useful for designing or evaluating the wastewater source heat pump.

关 键 词:城市原生污水 热泵系统 运行工况 参数特性 

分 类 号:TU831.6[建筑科学—供热、供燃气、通风及空调工程]

 