彩色多普勒血流会聚法测定主动脉瓣反流量的可行性探讨  被引量:1

Measurement of aortic regurgitant volume usingcolor doppler flow convergence method

在线阅读下载全文

作  者:孙品[1] 刘学秋[2] 王志斌[1] 李艳[1] 聂晶[1] 

机构地区:[1]青岛大学医学院附属医院,山东青岛266003 [2]济南市第四人民医院

出  处:《山东医药》2005年第33期5-6,共2页Shandong Medical Journal

摘  要:目的探讨彩色多普勒血流会聚(FC)法测定主动脉瓣反流量的可行性。方法近端血流会聚角呈水平型的单纯性主动脉瓣反流患者27例,分别用FC法和心导管技术测定主动脉瓣反流量。结果FC法和心导管测定的主动脉瓣每搏反流量分别为(60±27)cm3和(58±25)cm3(P>0.05),两者存在良好相关性(r=0.91,P<0.01)。结论对于近端血流会聚角为水平型的主动脉瓣反流患者,FC法能准确测定其主动脉瓣反流量。Objective: To investigate the reliability of color Doppler flow convergence method for measurement of regurgitant volume of aortic regurgitation. Methods.. Using color Doppler flow convergence method and cardiac catheterization, regurgitant volume was calculated in 27 patients with isolated aortic regurgitation and a flat proximal flow convergence angle. Results: The regurgitant volume calculated by color Doppler flow convergence method and cardiac catheterization was (60±27)cm^3 and (58±25)cm^3 respectively (P 〉0.05). There was an excellent correlation between the two methods (r=0.91, P〈0.01). Conclusions: The color Doppler flow convergence method provides reliable measurement of regurgitant volume in aortic regurgitation with a flat proximal flow convergence angle.

关 键 词:主动脉瓣反流 彩色多普勒 血流会聚法 

分 类 号:R445.1[医药卫生—影像医学与核医学]

 