转轮除湿复合式空调系统能耗研究  被引量:16

Research on Energy Consumption of a Rotary Desiccant Wheel Based Hybrid Air Conditioning System

在线阅读下载全文

作  者:刘瑞[1] 刘蔚巍[2] 

机构地区:[1]中国南车集团南京浦镇车辆厂,江苏南京210031 [2]上海交通大学,上海200030

出  处:《流体机械》2005年第12期69-72,共4页Fluid Machinery

摘  要:建立了转轮除湿复合式空调系统能耗的数学模型,并对其能耗进行计算与分析,结果表明:除湿能耗是影响总能耗的重要因素,采用新风先除湿再与回风混合的方式、室内排风作再生空气均可减小除湿能耗,降低总能耗;与传统空调系统相比,转轮除湿复合式空调系统具有较大的节能潜力,湿负荷越大,其优越性越明显。An energy consumption numerical model was developed. The calculation and analysis proves that energy consumption of dehumidification is an important factor affecting the total, and it can reduce the total energy consumption by adopting the method that fresh air is dehumidified before mixed with return air, or indoor exhaust is used as regeneration air. Compared with the conventional air conditioning svstem, the hybrid air conditioninz system can save energy, and more humidity load, more energy saving potential.

关 键 词:复合式空调 能耗 除湿转轮 节能 

分 类 号:TB6[一般工业技术—制冷工程]

 