摘 要:随着开关设备的大量采用,城市配电网的结构日趋复杂,采用面向对象的处理方法对配网进行可靠性等值,可以简化复杂电网的可靠性计算.针对配电网辐射状的特点,采用树型存储结构进行配电网计算并编制计算程序,用典型算例验证了算法的可行性,通过对典型算例的6种接线方案计算分析,得出了各种技术措施对配电网可靠性的影响程度的差异,为提高配电网可靠性提供了依据.City distribution network is getting more complex as a result of the use of a great many new switchgears. Using object - oriented technology (OOT), a complex network can be simplified a simple reliability calculation equivalent network. Based on the radiation characteristic of distribution network, tree data storage structure is put forward in this paper. A reliability calculation program is developed. The algorithm is verified through applying it to a typical sample. Six connecting modes are compared The difference between some normal measures of raising reliability are mentioned.