钎焊板式换热器的失效分析  被引量:3

Failure Analysis of Brazed Heat Exchanger

在线阅读下载全文

作  者:陈永东[1] 张明然[1] 艾志斌[1] 

机构地区:[1]合肥通用机械研究院,安徽合肥230031

出  处:《压力容器》2005年第12期39-42,35,共5页Pressure Vessel Technology

摘  要:钎焊板式换热器是一种应用场合日益增多的紧凑型高效换热器,但也暴露出一个显著的缺点,就是泄漏时(尤其是内漏时)不能修复。本文分析了某外国公司钎焊板式换热器的失效原因,指出要充分发挥该种换热器的性能特点,除严格控制其制造质量外,还应从设计与安装两方面进行失效预防。Brazed heat exchanger is a high efficient compact exchanger which has been widely used. It also has a fatal shortcoming . This exchanger can not be repaired once leakage happening (especially inside leakage). Some failure causes of brazed heat exchanger which produced by a foreign company were discussed in this paper. In order to keep good performance, the quality of brazed heat exchanger (such as brazing temperature) should be strictly controlled. The failure must be prevented both in design and installation.

关 键 词:钎焊 失效 水锤 

分 类 号:TQ051.5[化学工程]

 