检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]东北电力学院化学工程学院,吉林吉林132012 [2]中国石油吉林石化公司,吉林吉林132021
出 处:《化工科技》2005年第6期24-26,共3页Science & Technology in Chemical Industry
摘 要:采用曝气铁碳微电解工艺预处理高浓度有机酸性废水,研究了铁与碳质量比、反应时间对CODcr去除率等因素的影响。结果表明:在m(Fe)∶m(C)=4∶1、反应5 h的条件下,进水CODcr为1 675 mg/L和pH值1.77时,对CODcr的去除率为51.5%,废水的BOD5/CODcr值可由0.22提高到0.35,为酸性废水中和系统改造提供了科学依据。The aeration and Fe/C micro-electrolysis process were adopted in .treating chemical acidic wastewater of high concentration. The effects of Fe/C ratio and reaction time on the removal effici6ncy of CODcr etc. were studied. The results showed that when the ratio of Fe/C was 4 and reaction time was 5.0 hours,and when influent CODcr was 1 675 mg/L and pH was 1.77, the greatest removal efficiency of CODcr reached 51.5%, and the BODs/CODcr of chemical acidic wastewater was improved from 0.22 to 0.35. So a scientific basis of reference was provided for reforming neutralization system.
分 类 号:X783[环境科学与工程—环境工程]