检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中山大学物理系,广州510275 [2]中山大学肿瘤防治中心放疗科,广州510275
出 处:《中华放射医学与防护杂志》2005年第6期564-566,共3页Chinese Journal of Radiological Medicine and Protection
基 金:广东省自然科学基金资助项目(031563)
摘 要:目的基于高剂量率(HDR)后装治疗用的微型铱源(192Ir)结构,研究不锈钢外壳对其吸收剂量的影响。方法将微型铱源置于高10.5cm、直径11.1cm的圆柱形水模体中心,采用蒙特卡罗计算方法比较有无不锈钢外壳2种情况下铱源周围模体的剂量分布。结果在不锈钢外壳和水模的附近区域,2种情况下的剂量分布存在一定的差别。随着离源距离增加,剂量分布非常接近。结论近距离治疗中,不锈钢外壳在铱源剂量分布计算中的影响可以忽略。Objective Based on the structure of the ^192 Ir source used for high-dose-branchytherapy (HDR), the impact of the steel shell on the dose distribution was studied. Methods The ^192 Ir source was placed at the center of a cylindric water phantom which height was 10.5 cm and diameter was 11.1 cm. With Monte Carlo calculation the dose distribution in the phantom was compared between adding and not adding a steel shell. Results In the two situations, the relative dose difference was noted at the interface between the steel shell and the water phantom. Following the increase of the distance away from the source, the dose distribution rapidly became proximate. Conclusion The impact of the steel shell on the dose of the ^192 Ir source can be ignored.
分 类 号:TH789[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28