检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湖南大学信息与电气工程学院,湖南长沙410082
出 处:《华北电力技术》2006年第1期15-18,共4页North China Electric Power
基 金:国家自然科学基金资助(项目编号:50247006)
摘 要:为了对四相输电系统的经济性进行评估,以一条实际建设的500 kV紧凑型输电工程作为参照,对四相输电线路进行了模拟的简化设计和造价估算。在此基础上,讨论了单位电能输送成本与输电距离之间的关系,并通过对比三相与四相线路输送单位容量电能的造价对四相输电的经济性进行评估。研究表明,四相输电系统在经济上完全可行,具有良好的应用前景。For calculating the costs of four-phase power transmission system, this paper set a 500 kV constrained three phase power transmission project as a model and made simulated design and costs evaluation of four-phase power transmission system. And based on the design and evaluation data ,this paper also discusses the relationship between the power transmission costs and the power transmission distance. It concludes through the comparison of costs between three-phase and four-phase power transmission system that the four-phase power transmission system can reduce costs and has great application prospect.
分 类 号:TM721.2[电气工程—电力系统及自动化]