架空输电线路外绝缘配置方式及发展方向  被引量:11

Research on external-insulation-selection method and its future for overhead transmission lines

在线阅读下载全文

作  者:陈原[1] 姚文军[2] 张章奎[1] 王绍武[3] 沈燕生[2] 龚延兴[2] 王恒[2] 宿志一[4] 吴光亚[5] 巩学海[1] 

机构地区:[1]华北电力科学研究院有限责任公司,北京100045 [2]华北电网有限公司,北京100053 [3]国家电网公司,北京100031 [4]中国电力科学研究院,北京100085 [5]武汉高压研究所,湖北武汉430074

出  处:《中国电力》2006年第1期46-49,共4页Electric Power

摘  要:回顾架空输电线路外绝缘配置的发展过程,从污闪、风偏、雷击、鸟害、不明原因闪络、绝缘子老化等角度全面分析、比较现有线路外绝缘配置方式及产品。提出在防污闪涂料综合性能全面提高的前提下,发展由传统绝缘子(无机材质)与高质量防污闪涂料(有机材质)相结合的复合化玻璃(瓷)绝缘子产品,并实现工厂化、规模化生产,以有效提高线路外绝缘配置的综合质量,为特高压线路配置提供更合理的选择。The external insulation history of overhead transmission lines was given. Present external-insulation-selection method and external-insulation products of overhead lines were compared and analyzed. It is put forward that the composite glass or porcelain insulators combined with conventional insulators and high quality anti-contamination-flashover coating (e.g. PRTV) should be developed to improve the comprehensive quality of external insulation of lines, which can solve the problem of external-insulation-selection for UHV transmission lines.

关 键 词:线路 外绝缘 复合化 瓷绝缘子 玻璃绝缘子 

分 类 号:TM853[电气工程—高电压与绝缘技术]

 