检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]宁波大学建筑工程与环境学院,315221 [2]西安建筑科技大学土木工程学院,710055
出 处:《建筑结构》2006年第1期46-48,共3页Building Structure
基 金:陕西省自然科学研究计划项目(2002E213);宁波大学重点基金项目(Z200504)
摘 要:轴压比是影响柱抗震性能的一个主要因素,随着轴压比的增大,柱的抗震性能越来越差。从型钢混凝土柱正截面大、小偏心界限破坏时力的平衡条件出发,推导了型钢高强混凝土柱发生延性破坏的轴压力限值,并提出了其在不同抗震等级下轴压比限值,该限值可为型钢高强混凝土柱的抗震设计提供参考依据。Axial compression ratio is a main factor affecting the seismic performance of columns. With the increasing of it, the seismic performance of columns becomes poorer. The limit values of axial compression force in ductile damage for steel reinforced high-strength concrete(SRHC) columns is derived based on the balanced condition of forces in the case of balanced failure. Meanwhile, the limit values of axial compression ratio for steel reinforced high-strength concrete columns in various levels of earthquake resistance are presented, which can offer reference for seismic design of SRHC columns.