印刷电路板清洁度检测方法研究  被引量:2

Test Method Study on Printed Circuit Board Cleanness

在线阅读下载全文

作  者:丁昊冬[1] 胡荣宗[1] 黄维雄[1] 董瑞[1] 刘志铭[1] 

机构地区:[1]厦门大学化学系分析科学教育部重点实验室,福建厦门361005

出  处:《电子元件与材料》2006年第3期30-32,共3页Electronic Components And Materials

基  金:国家自然科学基金资助项目(20527005)

摘  要:对离子色谱法检测印刷电路板清洁度的IPC(电子电路互连和包装标准)方法做出了进一步改进,提出了水浴加热联合氮吹样品的前处理方法,有效的去除了异丙醇对测量的干扰,而且对样品进行了浓缩;对样品中的有机酸进行了有效的分离和检测。结果表明,该前处理方法干扰小,可以使检测结果更准确,检测限为3 ng/mL(以Cl–计)。The IPC's test method on cleanness of printed circuit board were improved. Water bath -heater combined with nitrogen-blow was proposed as a disposal method of sample. Interference of isopropanol on measure was removed effectively, and the sample was concentrated. Weak organic acids in the sample were separated effectively and examined successfully. The results show that this disposal method could make the result more exact, and its interference is small. The detection limit is 3 ng/mL (Cl^-).

关 键 词:电子技术 印刷电路板清洁度 离子色谱 氮吹 

分 类 号:TN707[电子电信—电路与系统]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象