摘  要:针对在负载电流有较大突变时补偿电路会产生较大畸变,以及三相电压畸变时ip-iq检测法存在的误差等问题,提出了一种改进的ip-iq检测法。在该检测法中加入了双电压闭环控制,以消除负载电流突变时产生的畸变;并采用一种新颖的基于低通滤波的A相正序电压提取单元代替原始ip-iq检测法的PLL锁相环,在三相电压畸变情况下仍可以正确提取A相正序电压,以精确检测出谐波和无功电流。研究和仿真结果表明,改进的ip-iq检测法在各种情况下都具有很好的补偿效果。Obvious distortion is caused by compensation circuits when load current varies promptly in a large scope. Distinct error occurs when ip-iq detecting approach is used in the case of unbalanced 3-phase voltage. As a solution, a developed detecting approach is proposed. Double close-loop control for DC link voltage is added to the method to achieve nice tracing performance of compensating current. A novel low pass lilting based positive-sequence voltage extracting unit substitutes for the original ip-iq PLL to ensure exact voltage of phase A is extracted even in case of imbalance three-phase voltage. Results of simulation show satisfying compensating effect with proposed detecting approach whereas mentioned original methods suffer errors.