1025t/h烟煤锅炉再热蒸汽温度偏差改进效果的实炉试验  被引量:2

Field Tests on Temperature Deviation Improvements of a 1025t/h Bituminous Coal Boiler' s Reheater.

在线阅读下载全文

作  者:吴贤辉 葛友康[1] 吴劲[1] 

机构地区:[1]嘉兴电厂筹建处,上海锅炉厂,浙江省电力试验研究所

出  处:《动力工程》1996年第2期22-24,39,共4页Power Engineering

摘  要:该文介绍引进型300MW机组锅炉、再热器系统经改进,减少再热蒸汽流量偏差和温度偏差的实炉试验结果。经过改进,末级再热器热偏差系数由原来的1.23减少到1.15,再热蒸汽温度最高值与最低值差由原来的67℃减少到35.4℃,提高了锅炉运行的安全性和可靠性。Abstract The paper describes the test results of improvement effects on a licensed 300MW set's boiler and its reheater for the purpose of diminishing reheater's mass flow and temperature deviations. The deviation coefficient in the last stage reheater dropped from the original 1 .23 to 1 .15 after improvement, and the difference between the maximum and minimum reheating temperature dropped from 67℃to 35.4℃, herewith increasing the boiler's operational safety and reliability.

关 键 词:电站锅炉 再热器 温度 偏差 烟煤 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 