检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:彭毅[1] 钟东[1] 钟立明[1] 张风涛[1] 叶建宇[1] 周晓初[1] 尹耀新[1] 熊沛[1]
机构地区:[1]北京大学深圳医院腔镜外科中心,深圳518036
出 处:《中国微创外科杂志》2006年第3期169-171,共3页Chinese Journal of Minimally Invasive Surgery
摘 要:目的探讨不用超声刀施行腔镜甲状腺手术的可行性。方法应用单极高频电刀行腔镜下甲状腺良性肿物切除术6例。结果全部病例手术均获成功。手术时间80-200min,平均110min;术中出血量25—50ml,平均36ml。术后24h下床活动,进流质饮食,无并发症。术后第2天拔颈部引流管,术后3~5d出院。结论高频电刀行腔镜甲状腺手术安全、可行。Objective To explore the feasibility of endoscopic thyroidectomy without the use of ultrasonic scalpel. Methods Monopolar high frequency electrosurgical unit was used to complete endoscopic thyroidectomy in 6 cases of thyroid benign tumors. Results All the operations were completed successfully. The operation time was 80 -200 min ( mean, 110 min) and the intraoperative blood loss was 25 - 50 ml ( mean,36 ml). The patients got out - of - bed activities and took liquid diets at a mean of 24 hours postoperatively. No complications was found. The drainage tube was removed on 2 days after operation and the patients were discharged from hospital at 3 ~ 5 days. Conclusions Use of high frequency electrosurgical unit for endoscopic thyroidectomy is safe and feasible.