单相并联型混合电力滤波器中谐波检测量的选取  被引量:3

Selection of harmonics detection components in single-phase parallel hybrid active power filter

在线阅读下载全文

作  者:孟庆波[1] 王志国 

机构地区:[1]西南交通大学电气工程学院,四川成都610031 [2]中铁十一局集团电务公司电气化分公司,湖北武汉430071

出  处:《电力自动化设备》2006年第4期90-92,共3页Electric Power Automation Equipment

摘  要:以单相混合型电力滤波器为对象,讨论了有源电力滤波器(APF)中谐波检测量的选取,即APF电压的不同表达式对混合电力滤波器滤波效果的影响。提出了5种APF电压表达式,这5种方式中后2种情况下都能使系统达到理想的滤波特性,一种是同时检测电网电流、负载电流和连接点处的电压;另一种是同时检测负载电流和连接点处的电压。The selection of harmonics detection components in APF(Active Power Filter) is discussed with the single-phase parallel hybrid active power filter as example,i.e, the effect of various APF voltage expressions on single-phase PHAPF(Parallel Hybrid Active Power Filter). Five kinds of APF voltage expression are brought forward,the 4th and 5th of which can realize ideal filtering,the former is detecting source current,load current and junction voltage simultaneously,and the later is detecting load current and junction voltage simultaneously.

关 键 词:并联混合型电力滤波器 有源电力滤波器 无源电力滤波器 谐波检测量 

分 类 号:TN713[电子电信—电路与系统]

 