机构地区:[1]西北工业大学自动化学院,陕西西安710072
出 处:《电瓷避雷器》2006年第2期7-11,14,共6页Insulators and Surge Arresters
基 金:航空基金项目;编号:04F53036
摘 要:绝缘子污秽闪络严重威胁着高压电网的可靠性。论述了人工污秽试验、污闪机理、污闪特征检测以及污闪模型建立等方面的研究现状,认为人工试验主要存在指标和污闪间的关系、电源配置及污秽模拟和运行现场的差异等问题。从工程的角度概括对比了可以有效用于污闪检测和风险预测的几种方法:距离判别法、模糊分类法、极值风险预测法及聚类分析法。指出解决污闪问题的关键是建立科学有效的污闪预测机制,基于模糊理论的信息融合法在污闪检测和风险预测上值得深入研究,而污闪模型研究就工程来讲,意义不大,并提出了未来防污闪工作的建议。Flashover of contaminated insulators, imperiling the reliability of high voltage power system severely, has been the hot point for researchers in high voltage and insulation field. In this pa- per, present status and problems such as artificial pollution test, mechanism studying, character detecting, and modeling in the research of flashover was summarized and compared. It is considered that the main problems existing in pollution test are correlation between test parameters and flashover values and difference of test power source from that of service site. Some kinds of methods that can be used for flashover identifying and risk predicting from monitored data was offered, such as distance judgement, fuzzy classification, limiting value risk prediction and information mergence. In the author's opinion, the key to solving the problem is developing effective and proper method for flashover predicting, where the fuzzy logical theory combing more information is worth of studying and flashover modeling hasn't too worthiness. Some suggestion about preventing and predicting flashover in the future were offered in the end of this paper too.
关 键 词:绝缘子污闪 人工污秽试验 污闪特征检测 污闪模型
分 类 号:TM85[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15