固相萃取-高效液相色谱法测定水中甲萘威  被引量:10

Determination of Carbaryl in Water by Solid-phase Extraction Coupled with High Performance Liquid Chromatography

在线阅读下载全文

作  者:苏宇亮 胡克武[1] 

机构地区:[1]珠海市供水总公司,珠海519020

出  处:《现代科学仪器》2005年第6期71-72,共2页Modern Scientific Instruments

摘  要:采用固相萃取,高效液相色谱法对水中甲萘威进行检测,通过实验研究,该法对水中甲萘威的最低检测限为0.001mg/L,相对标准偏差(RSD,n=5)≤2.5%,加标回收率为98.0%~98.5%,固相萃取效果优于液液萃取。该方法适合于地表水及饮用水中甲萘威的检测。The samples were first concentrated by solid phase extracfion(SPE), and then separated by HPLC method and detected by UV-VIS detector. The result of analyzing Carbaryl showed that the detection limit was 0.001mg/L. The RSD (n=5) was less than 2.5 % and the recycle rate was 98.0% - 98.5%. The result of solid phase extraction was better than liquid-liquid extraction. This method is suitable for determining Carbaryl in surface water and drinking water.

关 键 词:甲萘威 固相革取 高效液相色谱 

分 类 号:O657.72[理学—分析化学] O661.1[理学—化学]

 