正电子发射层析成像的鲁棒最小二乘重建  被引量:1

A Robust Least Squares Framework for PET Image Reconstruction

在线阅读下载全文

作  者:江晓娜[1] 刘华锋[1] 

机构地区:[1]浙江大学现代光学仪器国家重点实验室,杭州310027

出  处:《计算机辅助设计与图形学学报》2006年第4期598-601,共4页Journal of Computer-Aided Design & Computer Graphics

基  金:国家重点基础研究发展规划项目(2003CB716100);国家创新群体科学基金(60021201);浙江大学现代光学仪器国家重点实验室开放课题(LMOI-0403)

摘  要:提出的鲁棒最小二乘算法综合考虑了正电子发射层析成像中的各种误差,适用于实际正电子发射层析成像系统·实验结果表明:该算法比传统的最小二乘重建算法具有更加鲁棒的重建特性·In this paper, we propose a robust least squares solution for real position emission tomography (PET) system to minimizing the negative effect from the system matrix uncertainty on the final image. Compared with other algorithms at present, the robust least squares method proposed takes the noise fully into consideration. The performance of the algorithm is evaluated using the simulated phantom data, and the test result shows that a significant improvement in image quality over the conventional methods of least squares reconstruction is achieved.

关 键 词:正电子发射层析成像 鲁棒最小二乘算法 图像重建 

分 类 号:TP391.41[自动化与计算机技术—计算机应用技术]

 