摘  要:为了准确检测介质片在3mm频段的复介电特性,采用固定腔长法,研制了工作在101.80GHz的测试介质片复介电常数准光学谐振腔测试系统。结果表明:腔体的品质因数达8×10^4,高斯波束的束腰半径为2.36mm。复介电常数的测试范围ε’为2-8;tanδ为3×10^-4-5×10^-3,最可几误差为|△ε’/ε’|小于等于10%;|Δtanδ|小于等于20%tanδ+1×10^-4。此方法能检测大面积介质片复介电常数的均匀性。In order to measure accurately complex permittivity of dielectric materials (plate) at 101.80 GHz, a 3mm quasi-optical resonator syestm by using fixing resonator length method is prepared. The quality factor of the resonator is 8×10^4 and the redius of gauss beam is 2.36 mm. The range of measurable complex permittivity ε’ is 2-8;tanδ is 3×10^-4-5×10^-3,and the most probable measurement error is |Δε’/ε’|≤ 10 % ;|Δtanδ|≤20 % tanδ+1×10^-4. The complex permittivity uniformity of large-area sample can be measured by this system.

关 键 词:准光学谐振腔 介电常数 损耗角正切 品质因数 谐振频率 

分 类 号:TN973.3[电子电信—信号与信息处理] TM934.33[电子电信—信息与通信工程]

 