检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:邓黛青[1] 夏凤毅[2] 李光明[1] 周仰原[1] 赵修华[1]
机构地区:[1]同济大学污染控制与资源化研究国家重点实验室,上海200092 [2]浙江省温州师范学院,温州325027
出 处:《环境工程》2006年第2期11-13,共3页Environmental Engineering
基 金:国家"863"基金资助项目(2003AA644030)
摘 要:垃圾焚烧场的渗滤液具有pH低、污染成分复杂、COD_(Cr)浓度高、可生化性好等特点。本研究探索了UASB法处理焚烧场渗滤液时的快速启动方法,考察了水力停留时间、容积负荷对COD_(Cr)去除率的影响及产气量与COD_(Cr)去除率的关系,结果表明,在水力停留时间6d、容积负荷5kg/(m3.d)的情况下,COD_(Cr)去除率可达到93%,每升原水产气量可达22.5L,折合热值492.7kJ。Leachate from solid waste store-tank in municipal solid waste incinerators factory has the character of high organic contamination and low pH.The start-up performance of commercial-scale UASB reactors to treat leachate at ambient temperature was investigated.The experiment was also designed to investigate the effects of COD_(Cr) degrading efficient on HRT and VLD.The results indicate that at a HRT of 6 d and the VLD of 5 kg/(m 3 ·d),the COD_ Cr degrading efficiency is above 85%,and the gas produced from the organic contamination of each raw leachate is 22.5 L.
分 类 号:X705[环境科学与工程—环境工程] X792.03