出 处:《工业水处理》2006年第4期62-65,共4页Industrial Water Treatment
摘 要:研究了Fenton氧化与混凝耦合法处理有机氯农药废水的特性。以COD、色度去除率为指标比较了Fenton氧化、混凝、Fenton氧化与混凝耦合法处理有机氯农药废水的去除效果,也比较了处理后废水的可生化性。从技术角度,上述方法均能作为有机氯农药废水的预处理措施。通过经济分析,选取混凝法作为该废水的预处理措施。The characteristics of influential factors in treating organochlorine pesticide wastewater by Fenton oxidation and flocculation have preliminarily been investigated. The effects of Fenton oxidation, flocculation on the removal rate of COD and colority from organochlorine pesticide wastewater are compared. The value of B/C is slightly improved in the meantime. Based on the above results,three pretreatment techniques of organochlorine pesticide wastewater are feasible. By economic analysis, the flocculation is the only measure.
关 键 词:有机氯农药废水 FENTON氧化 混凝 经济分析
分 类 号:X703.1[环境科学与工程—环境工程] X786