检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王彦平[1] 戴建民[1] 于学洁[1] 史恩祥[1]
机构地区:[1]解放军第251医院
出 处:《护士进修杂志》1996年第6期11-12,共2页Journal of Nurses Training
摘 要:1994年2月~1995年10月,作者对医院临床内科氧气湿化瓶污染情况进行了调查。结果提示:湿化瓶的液体中存在大量的细菌生长,检出率为78.9%,以革兰氏阴性菌为主。选用三种消毒液浸泡湿化瓶消毒,(0.2%过氧乙酸,1:100"84"消毒液与0.1%的新洁尔灭)消毒效果相比较,P<0.01具有显著性。消毒后病人使用湿化瓶和干燥备用湿化瓶分别于第4天和第7天有细菌生长。消毒后湿化瓶,病人使用应每周消毒2次,干燥备用湿化瓶超过1周应重新消毒。The author conducted an investigation about the contaminated situation of oxygen humidifier of the hospital internal ward from Feb.1994 to Oct.1995. The result indicated:There were a great deal of bacteria growing in the humidifer liquid. The detectable rate was 78.9%,and they were mainly G-bacteria. Three kinds of sterilized liquids were selected to soak humidifier for sterilization(0.2% peracetic acid, 1: 100'84' sterilization liquid, 0.1% bromogeramine).The result was obviously different(P<0. 01). The patients used sterilized humidifier and dry-prepared humidifier, bacteria grew in the fourth day and seventh day respectively. So sterilized humidifier must sterilize two times every week and dry-prepared humidifier must sterilize once a week after patients used.