BESⅢ飞行时间计数器刻度的模拟研究  

Simulation study of the BESⅢ TOF calibration

在线阅读下载全文

作  者:蒋林立[1] 张黎明[1] 张子平[1] 伍健[1] 邵明[1] 毛泽普[2] 

机构地区:[1]中国科学技术大学近代物理系,安徽合肥230026 [2]中国科学院高能物理研究所,北京100039

出  处:《中国科学技术大学学报》2006年第3期310-314,共5页JUSTC

基  金:国家自然科学基金(10175060)资助

摘  要:基于GEANT4,完成了BESⅢ探测器单块飞行时间计数器的模拟,并对各类不同的带电粒子(e,μ,π,k,p),进行了仔细的时间刻度研究,发现质子的本征时间分辨最好.利用1.0 GeV/c电子的刻度参数用于不同动量的强子(π,k,p)修正时,发现存在一个与强子的速度β有关的系统时间偏移.改进时间刻度方法后可以基本消除这个偏移.Based on GEANT4, a simulation study on the time resolution was done for single scintillator counters used in BESⅢ (time-of-flight TOF) detector with different charged particles. It is found that proton has the best intrinsic time resolution. Applying the calibration constants from electrons of I'GeV/c momentum to other charged hadrons(π,k, p) of various momentum, time offsets are seen, which are found to be related to the velocity of hadrons. By correcting this effect in the calibration method, these time offsets can he satisfactorily eliminated to obtain better intrinsic time resolutions.

关 键 词:飞行时间计数器 BESⅢ GEANT4 本征时间分辨 刻度 时间系统偏移 