检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:卓忠雄[1] 高云华[1] 谭开彬[1] 王晓燕[1] 左松[1] 严鸿瑜[1] 黄嘉[1] 王红霞[1]
机构地区:[1]第三军医大学新桥医院超声科,重庆400037
出 处:《西部医学》2006年第3期343-344,共2页Medical Journal of West China
摘 要:目的寻求超声引导下肾脏组织活检最佳方法。方法对1086例印诊肾炎且需进行肾组织活检者,用不同方式进行肾组织活检。结果超声引导自动切割组一次性成功率最高,其次是引导手动切割组和引导负压组,盲法负压组一次成功率最低。而并发症各组之间的排序正好相反。结论超声引导自动肾穿刺活组织检查应推广应用。Objective To preferred way of kidney biopsy with ultrasonic guidance. Method 1086 cases of nephritis diagnosed and to kidney biopsy were undertaked with different method ultrasonic guidance. Result The achievement ratio of ultrasonic guidance automatic biopsy method is highest in all methods. The achievement ratio blind underpressure method is'lowest in all methods. The achievement ratio of ultrasonic guidance hand-motion and ultrasonic guidance blind underpressure method is higher the rather achievement ratio blind underpressure method. The complications were diametrical. Conclusion The ultrasonic guidance automatic biopsy method should are spreaded.
分 类 号:R445.1[医药卫生—影像医学与核医学]