基于低温辐射计高精度光辐射定标结果(1999和2003年)的对比研究  被引量:2

Comparison of Highly Accurate Optical Radiation Calibration Based on Cryogenic Radiometer Between 1999 and 2003 Year

在线阅读下载全文

作  者:李双[1] 王骥[1] 陈风[1] 张磊[1] 吴浩宇[1] 郑小兵[1] 

机构地区:[1]中国科学院安徽光学精密机械研究所遥感研究室,合肥230031

出  处:《激光与光电子学进展》2006年第5期67-70,共4页Laser & Optoelectronics Progress

摘  要:对1999年和2003年采用不同测量光路情况下可见光波段低温辐射计高精度光辐射定标测量结果及其不确定度进行了比较。结果表明,2003年低温辐射计激光功率测量不确定度比1999年的要小;2003年硅陷阱探测器光谱响应率测量不确定度和1999年的在同一水平上;陷阱探测器绝对光谱响应率变化在1.20%以内。这些结果证实陷阱探测器稳定性优良,光路改造合理。The results of highly accurate optical radiation calibration of cryogenic radiometer have been compared between year of 1999 and 2003. The results of comparison indicate that the laser power measure uncertainty of cryogenic radiometer of 2003 year is less than that of 1999 year, and the spectral responsivity measure uncertainty of Si trap detector of 2003 year is at the same level as in 1999; and the changing of trap detector responsivity is less 1.20%. The results prove the stability of trap detector and the reasonable improvement of light path.

关 键 词:辐射定标 低温辐射计 陷阱探测器 不确定度分析 

分 类 号:O432[机械工程—光学工程]

 