铁磁性材质铝翅片管的在役检测  被引量:3

Study of Inspection Technique of Aluminum Finned Ferromagnetic Tubes in Service

在线阅读下载全文

作  者:范智勇[1] 郑超雄[2] 李智军 

机构地区:[1]中国特种设备检测研究中心,北京100013 [2]大亚湾核电站,深圳518124 [3]欧宁管道管束检测技术有限公司,北京100102

出  处:《无损检测》2006年第5期233-236,241,共5页Nondestructive Testing

摘  要:铁磁性材质铝翅片管的在役检测是各种换热器管检测中难度最大的检测之一,常用的检测技术无法应用。为了找出其适用的在役检测方法,尝试了两种新的检测技术,即漏磁检测技术和超声内壁旋转检测技术,通过对带有人工缺陷的试样管分别进行检测试验,发现该两种技术应用于铁磁性材质铝翅片管检测的可行性和优缺点,最后结合试验结果进行分析,总结出铁磁性材质铝翅片管适用的在役检测方法。Aluminum finned ferromagnetic tubes in service are difficult to be inspect because conventional inspection techniques cannot be applied on. Two uncommon inspection techniques of MFL( Magnetic Flux Leakage) inspection and IRIS(Internal Rotary Inspection System) were tried to find the applicable inspection technique of aluminum finned ferromagnetic tubes. The applicability, advantage and disadvantage of the two techniques were found through the test of sample tubes with man-made defects respectively. And the applicable inspection technique of aluminum finned ferromagnetic tubes in service was concluded finally, by the analysis of the test and the characteristics of MFL and IRIS inspection techniques.

关 键 词:铝翅片管 漏磁检测 超声内壁旋转检测 危害性缺陷 