轮南电站燃气轮发电机组运行方式的试验研究  被引量:1

Experimental Study of Operation Modes for Gas Turbine Generator Units at Lun-nan Power Station

在线阅读下载全文

作  者:陈仁贵[1] 袁俊[1] 吴斌[2] 黄新[1] 

机构地区:[1]塔里木油田油气生产技术服务部,新疆库尔勒841000 [2]东北电力学院研究生部,吉林132012

出  处:《热能动力工程》2006年第3期307-310,共4页Journal of Engineering for Thermal Energy and Power

摘  要:通过对轮南电站燃气轮机甩负荷后机组转速动态飞升过程中的有关参数的分析,并分别对有差控制、无差控制、有差无差混合运行3种速度控制模式下机组所表现的动态特性进行了对比,根据燃气轮机机组本身特点和电站孤网运行现状,建议电站采用有差速度控制模式。Through an analysis of the relevant parameters associated with the process of dynamic-abrupt rise in rotation speed of Lun-nan Power Station gas turbine unit after a load rejection,the dynamic characteristics of the unit were compared when the latter assumes the following three speed control modes: droop control,zero-droop control,and droop and zero-droop mixed control.On the basis of the specific features of the gas turbine unit itself and the current status of isolated electric grid operation of the power station it is recommended that the power station should adopt a droop speed control mode.

关 键 词:燃气轮发电机组 甩负荷 速度控制模式 有差控制 无差控制 

分 类 号:TM611.24[电气工程—电力系统及自动化]

 