作 者:孔庆松[1] 郭廷翘[1] 龙玉巧 马丽英[1] 张虹[1] 王鑫[1] 李庆雷[1]
机构地区:[1]东北林业大学野生动物资源学院,哈尔滨医科大学心脏病生研究室,哈尔滨卷烟厂医院,哈尔滨轻型车厂职工医院
出 处:《哈尔滨医科大学学报》1996年第1期19-21,共3页Journal of Harbin Medical University
摘 要:本文首次用高效液相色谱(紫外检测器)测定褪黑激素(melatonin)。检测波长260nm,流动相为甲醇∶H2O=1∶1(V/V),(pH4.0),流速1ml/min。研究结果,样品重复性(峰面积)为±δx=48732.20±257.68,CV%为0.53%。结果表明,利用高效液相色谱(HPLC)测定褪黑激素远比目前应用的放射免疫试验、免疫组织化学法和气谱-质谱法简便、快速。High performance liquid chromatography (HPLC) of melatonin (standard and our synthetic) was carried out on Lichrosorb RP-18 column (controlled at 30℃),the compounds were determined by HPLC (ultraviolet detector) .Detective wavelength was 260nm.The mobile phase was mathanol:water=11 (pH4.0) ,the flow rate was 1ml/min. The study showed that repetition of melatonin was satisfactory ( CV%0.53%~0.87%) .rate of recovery was 100.53%~106.60%.The study also showed that this method was far more buperior than most of thoes used at present.