作 者:许钟麟[1] 张益昭[1] 王清勤[1] 刘华[1] 温风[1] 冯昕[1] 张彦国[1] 赵力[1] 王荣[1] 牛维乐[1] 姚丹[1] 于玺华[2] 易新文 欧燕川 卢伟明
机构地区:[1]中国建筑科学研究院 [2]中国人民解放军第302医院 [3]广东申菱空调设备有限公司
出 处:《暖通空调》2006年第5期1-4,共4页Heating Ventilating & Air Conditioning
摘 要:基于大气尘实验,研究了隔离病房开门时温差对污染物外泄的作用.结果显示,温差作用是一般压差作用抵消不了的;2℃温差时污染物交换量比0℃温差时增加50%左右;缓冲室可对温差作用引起的污染物交换起到15~30倍的动态隔离作用.Based on the atmospheric dust experiment, researches the contaminant air exchange caused by the temperature difference while opening the door of isolation wards. Concludes that the undesired effect of temperature difference could not be eliminated just by the negative pressure difference between adjacent rooms, that the contaminant air exchange would increase about 50% in the temperature difference of 2℃ than that in the temperature difference of 0℃, and that such contamination could be reduced to about 1/31~1/16 with the helo of buffer rooms.
分 类 号:TU831.8[建筑科学—供热、供燃气、通风及空调工程]