中性束诊断电源系统及束流引出实验研究  

Power system for diagnostic neutral beam and study on the experiment of neutral beam extraction

在线阅读下载全文

作  者:张健[1] 刘保华[1] 胡立群[1] 杜少武[2] HT-7DNB组 

机构地区:[1]中国科学院等离子体物理研究所,合肥230031 [2]合肥工业大学能源研究所,合肥230009

出  处:《核聚变与等离子体物理》2006年第2期151-155,共5页Nuclear Fusion and Plasma Physics

摘  要:HT-7中性束诊断电源系统的计算机控制系统由PLC、工控机、逻辑控制和定时单元等组成。对起弧、束流引出等实验进行了研究。在多种参数下,通过调节弧压、进气量等观察了其对弧流的影响。初步实验结果表明,在高压35kV、弧流80A的情况下,束电流可以达到3.6A,引出的中性束流功率可以稳定地达到50kW以上。Control system of power supply for HT-7 diagnostic neutral beam source was composed of PLC, timer and master control logic. The experimental results show the good facility and reliability. The arcing and beam extraction are studied experimentally. The influences on the beam current are observed by adjusting arc voltage and gas injection at different cases. The neutral beam power of 50kW and beam current about 3.6A were obtained in this operation priod with 35kV HV and 80A arc current.

关 键 词:中性束诊断 电源系统 HT-7 

分 类 号:TL623[核科学技术—核技术及应用]

 